<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
  <channel>
    <title>AEC Assistant guides</title>
    <link>https://www.aecassistant.com.au/news</link>
    <atom:link href="https://www.aecassistant.com.au/news/rss.xml" rel="self" type="application/rss+xml" />
    <description>Guides to the National Construction Code, the standards it references and Australian planning rules, every figure cited to the clause.</description>
    <language>en-au</language>
    <lastBuildDate>Thu, 24 Sep 2026 02:00:00 GMT</lastBuildDate>
    <item>
      <title>Roof and Stormwater Drainage Calculators to AS/NZS 3500.3:2025</title>
      <link>https://www.aecassistant.com.au/news/roof-stormwater-drainage-calculators-as-nzs-3500-3</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/roof-stormwater-drainage-calculators-as-nzs-3500-3</guid>
      <pubDate>Thu, 24 Sep 2026 02:00:00 GMT</pubDate>
      <description>Free calculators for roof drainage, box gutters, site stormwater and water supply, applying the methods NCC 2025 calls up, AS/NZS 3500.3:2025 and 3500.1:2025, and showing their working clause by clause. What each one sizes, where the Standard applies, and how the numbers were checked.</description>
    </item>
    <item>
      <title>AEC Assistant Update 5: A New Tuned Model, a Deeper Read of Your Drawings, and Longer Work Ahead</title>
      <link>https://www.aecassistant.com.au/news/aec-assistant-update-5-more-capable-model-drawings-longer-work</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/aec-assistant-update-5-more-capable-model-drawings-longer-work</guid>
      <pubDate>Wed, 23 Sep 2026 05:00:00 GMT</pubDate>
      <description>AEC Assistant keeps getting better: a new tuned model that follows a question through related provisions, a deeper read of your drawings and clause clips, answers that keep going when you close the tab, and longer-running work on the way.</description>
    </item>
    <item>
      <title>Luminance Contrast Calculator: The AS 1428.1 30% Rule, LRV and the Bowman-Sapolinski Equation (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/luminance-contrast-calculator-as-1428-1-30-percent-lrv</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/luminance-contrast-calculator-as-1428-1-30-percent-lrv</guid>
      <pubDate>Mon, 21 Sep 2026 06:00:00 GMT</pubDate>
      <description>Where AS 1428.1:2021 asks for 30% luminance contrast (doorways, stair nosing strips, the line on frameless glazing, toilet seats), how the Bowman-Sapolinski equation in Appendix B turns two light reflectance values into a contrast figure, why LRV 40 against 70 fails while LRV 5 against 30 passes, the 45% and 60% for tactile indicators, and a calculator that runs the equation for your pair.</description>
    </item>
    <item>
      <title>NCC D2D18 Explained: Number of Persons Accommodated and Table D2D18 Area per Person (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/ncc-d2d18-number-of-persons-accommodated-table-explained</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-d2d18-number-of-persons-accommodated-table-explained</guid>
      <pubDate>Mon, 21 Sep 2026 06:00:00 GMT</pubDate>
      <description>How NCC Volume One D2D18 sets the number of persons a storey, room or mezzanine is assessed for: the floor area of each part divided by the Table D2D18 figure for its use, with lifts, stairs, corridors, lobbies, ducts and sanitary compartments left out; or a seating count; or another suitable assessment. The full table, the NSW version, a worked office example, the clauses that then use the number, and a calculator that runs the method.</description>
    </item>
    <item>
      <title>NCC D3D14 Goings and Risers: Table D3D14 Stair Dimensions Explained (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/ncc-d3d14-goings-and-risers-stair-dimensions-explained</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-d3d14-goings-and-risers-stair-dimensions-explained</guid>
      <pubDate>Mon, 21 Sep 2026 06:00:00 GMT</pubDate>
      <description>Clause D3D14 of NCC Volume One sets every stair dimension for a Class 2 to 9 building: 2 to 18 risers a flight, Table D3D14's riser, going and 2R + G limits, the 5 mm and 10 mm constancy rule, the 125 mm sphere, slip resistance, solid treads, the Class 9b 36-riser rule and winders. Every sub-clause explained, with the NSW variation, the Housing Provisions equivalent and a checker for your flight.</description>
    </item>
    <item>
      <title>NCC D3D17 Barriers to Prevent Falls: When a Balustrade Is Required (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/ncc-d3d17-barriers-to-prevent-falls-explained</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-d3d17-barriers-to-prevent-falls-explained</guid>
      <pubDate>Mon, 21 Sep 2026 06:00:00 GMT</pubDate>
      <description>Clause D3D17 of NCC Volume One is the trigger for a balustrade: a continuous barrier along the side of a stair, ramp, floor, balcony, mezzanine, accessible roof or path where the trafficable surface is 1 m or more above the surface beneath. The four locations, the four exclusions, the construction rules in D3D18 to D3D21 it calls up, the NSW variation, the Housing Provisions equivalent for a house, and a checker for your edge.</description>
    </item>
    <item>
      <title>NCC D3D22 Handrails: The Clause Explained Sub-clause by Sub-clause (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/ncc-d3d22-handrails-explained</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-d3d22-handrails-explained</guid>
      <pubDate>Mon, 21 Sep 2026 06:00:00 GMT</pubDate>
      <description>Clause D3D22 of NCC Volume One sets the handrail rule for every stair and ramp in a Class 2 to 9 building: one side, both sides at 2 m wide, the top not less than 865 mm above the nosings, continuous between landings, the second lower rail in primary schools and early childhood centres, AS 1428.1 in an accessible exit, the health-care and aged care corridor rails, and the separate rules for a stair inside an apartment. Every sub-clause explained.</description>
    </item>
    <item>
      <title>Ramp Requirements in Australia: NCC and AS 1428.1 Gradients, Landings, Handrails and a Free Ramp Calculator (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/ncc-ramp-requirements-gradient-1-in-14-as-1428-1-calculator</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-ramp-requirements-gradient-1-in-14-as-1428-1-calculator</guid>
      <pubDate>Mon, 21 Sep 2026 06:00:00 GMT</pubDate>
      <description>The gradient an accessible ramp may have (1:14), where it becomes a walkway (1:20), how far it can run before a landing (9 m), the 1000 mm width, the 1:40 crossfall, handrails both sides with 300 mm extensions and the 65 mm kerb, with the step, threshold and kerb ramps that sit beside them. Every figure from AS 1428.1:2021 and the NCC clause that calls it up, and a calculator that checks your rise and length.</description>
    </item>
    <item>
      <title>NCC Sanitary Facilities: How Many Toilets a Building Needs, Table F4D4 and a Free Calculator (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/ncc-sanitary-facilities-calculator-f4d4-toilets-basins</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-sanitary-facilities-calculator-f4d4-toilets-basins</guid>
      <pubDate>Mon, 21 Sep 2026 06:00:00 GMT</pubDate>
      <description>How many closet pans, urinals and washbasins a Class 3 to 9 building needs under NCC Volume One Part F4: count the people, split them by sex, read the band in the right F4D4 table and round any part of the next band up. The tables for offices, factories, shops, restaurants and schools, the accessible and ambulant compartments that sit on top, the unisex and all-gender options, the state variations, and a calculator that draws the bank of fixtures for your numbers.</description>
    </item>
    <item>
      <title>Gutter and Downpipe Sizing in Australia: The NCC Tables, AS/NZS 3500.3 and a Free Calculator (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/gutter-downpipe-sizing-calculator-ncc-as-nzs-3500-3</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/gutter-downpipe-sizing-calculator-ncc-as-nzs-3500-3</guid>
      <pubDate>Mon, 21 Sep 2026 04:00:00 GMT</pubDate>
      <description>How eaves gutters, downpipes and overflow measures are sized under NCC 2025: the 5-minute rainfall intensity for your locality, the gutter type from Table 7.4.3a, the 12 m per downpipe rule and the overflow volume the gutter must shed in a 1% AEP storm. Every table, the Code's own worked example, and a calculator that runs the method for your roof.</description>
    </item>
    <item>
      <title>NCC Fire-Resistant Building Elements: How an FRL Is Proved, the Deemed Thickness Tables for Walls, Columns and Beams, and What a House Needs (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/ncc-fire-resistant-building-elements-frl-deemed-thickness-tables</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-fire-resistant-building-elements-frl-deemed-thickness-tables</guid>
      <pubDate>Thu, 17 Sep 2026 22:00:00 GMT</pubDate>
      <description>A wall, column, floor or beam is a fire-resistant building element when it holds a fire-resistance level, and NCC Volume Two Specification 1 sets the six ways to prove one: the deemed thickness tables, a tested prototype, an assessment of a near-identical element, a design to the structural standard, a calculation, or the fire-protected timber route. This guide walks through each with the clause, reproduces the deemed tables for masonry, concrete and gypsum walls and for protected steel, explains the Specification 2 detailing rules that come with them, shows where a house needs one, and includes a finder for steel column and beam protection.</description>
    </item>
    <item>
      <title>NCC Fire Resistance Levels (FRL) Explained: What 90/60/30 Means, Type A, B and C Construction, and the FRL Your Wall Needs (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/ncc-frl-fire-resistance-levels-explained-type-a-b-c-construction</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-frl-fire-resistance-levels-explained-type-a-b-c-construction</guid>
      <pubDate>Tue, 15 Sep 2026 22:00:00 GMT</pubDate>
      <description>An FRL is three numbers in minutes: structural adequacy, integrity and insulation, in that order, from the AS 1530.4 furnace test. Which FRL a wall, column, floor or roof needs comes from the building's class, its rise in storeys (which sets Type A, B or C construction) and, for external walls, its distance from a boundary or another building. This guide explains each step with the clause, and the finder below reads the Specification 5 tables for your element.</description>
    </item>
    <item>
      <title>NCC Handrail Requirements: Height, Where They Are Required, Extensions and Landings (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/ncc-handrail-requirements-height-stairs-ramps-landings</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-handrail-requirements-height-stairs-ramps-landings</guid>
      <pubDate>Thu, 10 Sep 2026 02:00:00 GMT</pubDate>
      <description>The NCC handrail rule for a house is one rail, on one side, with its top at least 865 mm above the nosings. A commercial stair adds a second rail once it is 2 m wide, and an accessible stair adds a 1000 mm maximum, both sides, a 30 to 52 mm grip and 300 mm extensions. This guide sets out each rule with its clause, and the checker below draws the rail for your stair.</description>
    </item>
    <item>
      <title>NCC Insulation Requirements: R-Values for Roofs, Walls and Floors by Climate Zone (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/ncc-insulation-requirements-r-values-by-climate-zone</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-insulation-requirements-r-values-by-climate-zone</guid>
      <pubDate>Tue, 08 Sep 2026 23:00:00 GMT</pubDate>
      <description>The minimum insulation R-value for a house ceiling, wall or floor is read from the climate-zone tables in Part 13.2 of the ABCB Housing Provisions. This guide gives the headline NCC 2025 figures for the common cases in all eight zones, plus the thermal bridging, reflective foil, solar absorptance, edge-reduction and condensation rules around them.</description>
    </item>
    <item>
      <title>Fire-Rated Walls for Houses: NCC 900 mm Boundary Rule, FRL 60/60/60 and Party Walls (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/ncc-fire-rated-walls-houses-900mm-boundary-rule</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-fire-rated-walls-houses-900mm-boundary-rule</guid>
      <pubDate>Mon, 07 Sep 2026 23:00:00 GMT</pubDate>
      <description>When a house wall must be fire-rated under the NCC: the 900 mm boundary and 1.8 m building-to-building rules in Housing Provisions 9.2.1, what FRL 60/60/60 means, openings and eaves near the boundary, separating walls to 9.3.1, service penetrations, garage exemptions, and the SA, NSW and WA variations.</description>
    </item>
    <item>
      <title>BAL Ratings Explained: Bushfire Attack Levels from BAL-LOW to BAL-FZ (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/bal-ratings-explained-bushfire-attack-level-as-3959</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/bal-ratings-explained-bushfire-attack-level-as-3959</guid>
      <pubDate>Sun, 06 Sep 2026 23:00:00 GMT</pubDate>
      <description>The six Bushfire Attack Levels in AS 3959:2018, the radiant heat each one represents, how an assessor derives a BAL from fire danger index, vegetation, distance and slope, what each level requires for walls, windows, roofs and decks, and where the NCC and the state schedules change the rules.</description>
    </item>
    <item>
      <title>NCC Balustrade Requirements: Heights, Gaps, Climbability, Glass and Wire Barriers (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/ncc-balustrade-requirements-height-gaps-glass-wire</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-balustrade-requirements-height-gaps-glass-wire</guid>
      <pubDate>Sat, 05 Sep 2026 23:00:00 GMT</pubDate>
      <description>Every NCC balustrade figure in one place: the 1 m fall trigger, 1 m and 865 mm heights, the 125 mm sphere and 40 mm face gap, the 150 to 760 mm climbability zone above 4 m, wire barrier tables, AS 1288 glass rules and the 2 m and 4 m openable window limits.</description>
    </item>
    <item>
      <title>NCC Ceiling Heights: Minimum Room Heights for Houses and Commercial Buildings (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/ncc-ceiling-heights-minimum-room-heights</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-ceiling-heights-minimum-room-heights</guid>
      <pubDate>Fri, 04 Sep 2026 23:00:00 GMT</pubDate>
      <description>Every NCC minimum ceiling height in one place: 2.4 m habitable rooms, 2.1 m kitchens, bathrooms and garages, 2.0 m over stairs, the two-thirds rule for raked ceilings and attics, and the Volume One figures for apartments, offices, schools and hospitals.</description>
    </item>
    <item>
      <title>NCC Climate Zones Explained: The 8 Zones, How to Find Yours, and What Changes Between Them (2025)</title>
      <link>https://www.aecassistant.com.au/news/ncc-climate-zones-explained-map-what-changes-by-zone</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-climate-zones-explained-map-what-changes-by-zone</guid>
      <pubDate>Fri, 04 Sep 2026 04:44:31 GMT</pubDate>
      <description>The eight NCC climate zones explained: what each one means, how to find the zone for any address (Sydney is two zones), why NCC and NatHERS zones differ, and what NCC 2025 changes between them for insulation, roof colour, wall membranes and the drained cavity now mandatory in zones 6, 7 and 8 (outside NSW and Tasmania).</description>
    </item>
    <item>
      <title>AEC Assistant Update 4: Faster Answers, NCC 2025 by Default, Projects That Know Their Site</title>
      <link>https://www.aecassistant.com.au/news/aec-assistant-update-4-ncc-2025-projects-sharing</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/aec-assistant-update-4-ncc-2025-projects-sharing</guid>
      <pubDate>Wed, 02 Sep 2026 04:25:17 GMT</pubDate>
      <description>The biggest release since launch: faster and more thorough answers, NCC 2025 answered by default in every state, projects that fetch zoning and overlays from the address, sharing across your firm, public answer links, an installable app and seven free NCC calculators. With screenshots.</description>
    </item>
    <item>
      <title>NCC Stair Requirements: Risers, Goings, Handrails and Balustrades (2025 Guide)</title>
      <link>https://www.aecassistant.com.au/news/ncc-stair-requirements-risers-goings-handrails-balustrades</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-stair-requirements-risers-goings-handrails-balustrades</guid>
      <pubDate>Wed, 02 Sep 2026 03:26:48 GMT</pubDate>
      <description>Every NCC 2025 stair dimension for a house and a commercial building, with the clause behind each figure: riser 115 to 190 mm, going 240 to 355 mm, 2R + G between 550 and 700, 865 mm handrails, 1 m barriers and the 125 mm sphere test. Two diagrams and a free calculator.</description>
    </item>
    <item>
      <title>NCC 2025: What Changed, and When Your State Adopts It</title>
      <link>https://www.aecassistant.com.au/news/ncc-2025-changes-state-adoption-dates</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-2025-changes-state-adoption-dates</guid>
      <pubDate>Tue, 01 Sep 2026 06:43:44 GMT</pubDate>
      <description>NCC 2025 became available for adoption on 1 May 2026. Four months on, it is still not the code most Australian projects are assessed against. Who is on it, who is not, and what changed at clause level.</description>
    </item>
    <item>
      <title>Waterproof vs Water-Resistant: The AS 3740:2021 Materials Lists and the Compatibility Chain</title>
      <link>https://www.aecassistant.com.au/news/as-3740-waterproof-vs-water-resistant</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/as-3740-waterproof-vs-water-resistant</guid>
      <pubDate>Tue, 01 Sep 2026 04:09:43 GMT</pubDate>
      <description>AS 3740:2021 sorts every wet-area material into waterproof or water-resistant, in Clause 3.3. The lists as a working reference, the NCC clauses that decide which label applies, and the compatibility chain in Appendix E that most failures break.</description>
    </item>
    <item>
      <title>Victoria's Townhouse and Low-Rise Code (Clause 55): The Numbers, the Standards and How to Lodge</title>
      <link>https://www.aecassistant.com.au/news/victoria-townhouse-and-low-rise-code-clause-55</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/victoria-townhouse-and-low-rise-code-clause-55</guid>
      <pubDate>Tue, 01 Sep 2026 03:40:17 GMT</pubDate>
      <description>Victoria's Townhouse and Low-Rise Code replaced ResCode at Clause 55 on 31 March 2025. Meet every applicable standard and the application is exempt from objector appeal. The numbers, the standards list, the documents to lodge, and the traps, verified against the May 2025 Guidelines.</description>
    </item>
    <item>
      <title>AS 3740:2021 Explained: Scope, Changes from 2010, and How the NCC Calls It Up</title>
      <link>https://www.aecassistant.com.au/news/as-3740-2021-waterproofing-guide</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/as-3740-2021-waterproofing-guide</guid>
      <pubDate>Tue, 01 Sep 2026 03:06:26 GMT</pubDate>
      <description>AS 3740:2021 is the edition NCC 2025 calls up in its wet-area provisions. What it covers, what changed from 2010 with clause references, which NCC clause calls it up for your building class, and the numbers to keep at hand.</description>
    </item>
    <item>
      <title>AS 4000:2025 General Conditions of Contract: What Changed and Why It Matters</title>
      <link>https://www.aecassistant.com.au/news/as-4000-2025-general-conditions-of-contract-changes</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/as-4000-2025-general-conditions-of-contract-changes</guid>
      <pubDate>Thu, 04 Jun 2026 12:49:04 GMT</pubDate>
      <description>AS 4000:2025, released in June 2025, replaced the 1997 general conditions. The headline changes with clause numbers: GST, PPSA, WHS principal contractor, dispute resolution, and what to fix in your templates.</description>
    </item>
    <item>
      <title>From search tool to decision engine: AEC Assistant Update 3</title>
      <link>https://www.aecassistant.com.au/news/from-search-tool-to-decision-engine-aec-assistant-update-3</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/from-search-tool-to-decision-engine-aec-assistant-update-3</guid>
      <pubDate>Thu, 04 Jun 2026 07:50:10 GMT</pubDate>
      <description>We named the problem. We published the architecture. Now we've shipped it: AEC Assistant rebuilt around projects, memory and cited, project-specific compliance answers. There's a free plan, so bring a real question and put it to the test.</description>
    </item>
    <item>
      <title>How a Building Learns to Think</title>
      <link>https://www.aecassistant.com.au/news/how-a-building-learns-to-think</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/how-a-building-learns-to-think</guid>
      <pubDate>Fri, 22 May 2026 05:44:11 GMT</pubDate>
      <description>Three of the most credible analyst voices in construction technology published their theses within weeks of each other. McKinsey on agentic services. Andreessen Horowitz on the system-of-record era ending. Zacua Ventures on AI across the construction value chain. All three arrived at the same structural observation we articulated in The Infrastructure Beneath the Infrastructure in March: the industry needs an intelligence layer, not more tools. The question is no longer whether. The question is how you build one that actually works. This article is our answer. Decision Intelligence Infrastructure (DII™) is a six-floor architecture. Each floor compounds on the floors beneath it. Most of the industry sits between the ground and second levels. The key challenge is not technical but human: institutional intelligence leaves when a project demobilises or when staff depart. Australia serves as a rigorous test case for any architecture aspiring to reach the sixth floor. We are building from this context and publishing the framework openly.</description>
    </item>
    <item>
      <title>The Infrastructure Beneath the Infrastructure.</title>
      <link>https://www.aecassistant.com.au/news/the-infrastructure-beneath-the-infrastructure</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/the-infrastructure-beneath-the-infrastructure</guid>
      <pubDate>Sat, 28 Mar 2026 08:12:21 GMT</pubDate>
      <description>By Matthew Secatore - Co-Founder of AEC Assistant 15 min read · Construction · Decision Intelligence · AEC Compliance · Infrastructure · AI</description>
    </item>
    <item>
      <title>The Block 2025 Bathroom Week: What the Reveals Show About AS 3740 and the Housing Provisions</title>
      <link>https://www.aecassistant.com.au/news/block-2025-week-1-bathroom-waterproofing-compliance</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/block-2025-week-1-bathroom-waterproofing-compliance</guid>
      <pubDate>Mon, 04 Aug 2025 07:09:02 GMT</pubDate>
      <description>The Block 2025 bathroom week: adhesive failures, high vanities and an unfinished room. Every one of those maps to a clause, and the clauses for a Class 1 house are not the ones most articles cite. A verified checklist for waterproofing, ventilation, livable housing, electrical and plumbing.</description>
    </item>
    <item>
      <title>NCC 2022 Amendment 2: Every Change, and What to Re-check</title>
      <link>https://www.aecassistant.com.au/news/ncc-2022-amendment-2-key-changes-you-need-to-know</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ncc-2022-amendment-2-key-changes-you-need-to-know</guid>
      <pubDate>Tue, 29 Jul 2025 13:03:58 GMT</pubDate>
      <description>NCC 2022 Amendment 2 took effect on 29 July 2025. It references AS 1428.1:2021 and rewrites D3D22, D4D4 and Volume Three E1D2. Every change, what did not change, and what to re-check.</description>
    </item>
    <item>
      <title>AEC Assistant Update 1 (July 2025)</title>
      <link>https://www.aecassistant.com.au/news/aec-assistant-month-one-round-up</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/aec-assistant-month-one-round-up</guid>
      <pubDate>Wed, 23 Jul 2025 05:10:38 GMT</pubDate>
      <description>Month one of AEC Assistant (July 2025): jurisdiction-aware search, multi-image queries, team plans and two new calculators. Superseded; see Update 3 for the current product.</description>
    </item>
    <item>
      <title>Ventilated Rainscreen Facades and NCC Section J: Thermal Bridging, R-values and the Clauses That Apply</title>
      <link>https://www.aecassistant.com.au/news/ventilated-rainscreen-facades-ncc-section-j</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/ventilated-rainscreen-facades-ncc-section-j</guid>
      <pubDate>Tue, 13 May 2025 13:17:46 GMT</pubDate>
      <description>How a ventilated rainscreen wall works, why thermal bridging decides its real R-value, and where the requirements sit in NCC 2025: J4D3, J4D6 and Specification 37 in Section J, and F8D3 for condensation.</description>
    </item>
    <item>
      <title>Systemic Risks in the Australian Architecture Sector: The ARBV and NSW ARB Report Explained</title>
      <link>https://www.aecassistant.com.au/news/systemic-risks-australian-architecture</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/systemic-risks-australian-architecture</guid>
      <pubDate>Mon, 12 May 2025 12:03:19 GMT</pubDate>
      <description>The ARBV and NSW ARB joint report on systemic risks in the architecture sector (October 2022): D&amp;C procurement, client agreements, NCC compliance and the climate and technology disruptors, with what a practice can do about each.</description>
    </item>
    <item>
      <title>Mother’s Day 2025: Honouring the Women Building Australia’s Future</title>
      <link>https://www.aecassistant.com.au/news/mothers-day-2025-honouring-the-women-building-australias-future</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/mothers-day-2025-honouring-the-women-building-australias-future</guid>
      <pubDate>Sun, 11 May 2025 04:47:31 GMT</pubDate>
      <description>On Mother's Day 2025 we look at the women balancing AEC careers with parenthood: participation figures, the parental leave rules from 1 July 2024, and what practices can do to keep them.</description>
    </item>
    <item>
      <title>AS/NZS 3500:2025: What Changed and When It Applies</title>
      <link>https://www.aecassistant.com.au/news/as-nzs-3500-2025-plumbing-drainage-changes</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/as-nzs-3500-2025-plumbing-drainage-changes</guid>
      <pubDate>Tue, 06 May 2025 13:21:02 GMT</pubDate>
      <description>Standards Australia published the 2025 editions of AS/NZS 3500 Parts 1 to 4 on 17 April 2025. Victoria made them mandatory on 20 October 2025; everywhere else they arrive with NCC 2025. The changes, clause by clause.</description>
    </item>
    <item>
      <title>Welcome to the AEC Assistant Blog</title>
      <link>https://www.aecassistant.com.au/news/blog-post-1-introducing-our-founders</link>
      <guid isPermaLink="true">https://www.aecassistant.com.au/news/blog-post-1-introducing-our-founders</guid>
      <pubDate>Sat, 30 Nov 2024 13:00:00 GMT</pubDate>
      <description>Introducing our founders, Andrew Galea and Matthew Secatore, and why we started AEC Assistant.</description>
    </item>
  </channel>
</rss>
